Every Published Output Figure in This Category, in One Table

Medically reviewed by

4 independent reviewers

Andrew Conrad Barile, kinésithérapeute, DPT

Andrew Conrad Barile, kinésithérapeute, DPT

Doctorat en physiothérapie (DPT), physiothérapeute agréé (PT)

Read bio

Le Dr Andrew Conrad Barile est docteur en physiothérapie et PDG ainsi que fondateur de Xtreem Pulse LLC. Il a obtenu son doctorat en physiothérapie à Daemen College et possède plus de vingt ans d'expérience clinique et entrepreneuriale en physiothérapie pédiatrique, thérapie craniosacrale et innovation en dispositifs médicaux. Sa profonde connaissance de l'anatomie humaine, de la physiologie musculaire et des technologies thérapeutiques offre une approche scientifique précieuse pour le rajeunissement du visage et les solutions anti-âge.

Bertica M. Rubio, M.D.

Bertica M. Rubio, M.D.

Directeur Médical, Clinique de Médecine Régénérative Anti-âge | Médecin Certifié par le Conseil | École de Médecine de Dartmouth

Read bio

Le Dr Bertica M. Rubio est une médecin certifiée et directrice médicale de la clinique de médecine régénérative anti-âge à Redlands, en Californie. Elle a obtenu son Bachelor of Science à l'Université Loyola Marymount et son Doctorat en médecine à la Dartmouth Medical School (Geisel School of Medicine). Elle a effectué sa résidence en pédiatrie au UC Irvine Medical Center.

Forte de plusieurs décennies d'expérience clinique, le Dr Rubio est spécialisée en médecine de gestion du vieillissement, médecine régénérative, cicatrisation des plaies et thérapies par facteurs de croissance. Sa pratique intègre la science médicale fondée sur des preuves avec des traitements esthétiques et régénératifs avancés, aidant les patients à atteindre une santé optimale et une vitalité juvénile.

Le Dr Rubio est passionnée par l'éducation des patients sur la science derrière les soins de la peau, le rajeunissement du visage et les technologies non invasives comme l'EMS (stimulation électrique musculaire) pour le tonus facial. Ses articles pour PureLift LAB allient connaissances médicales rigoureuses et conseils pratiques pour obtenir des résultats réels et durables.

Daniel Grinberg, MD, FACS

Daniel Grinberg, MD, FACS

Otolaryngologiste et chirurgien de la tête et du cou certifié par le conseil | Membre, American College of Surgeons | Professeur clinique adjoint, Mount Sinai School of Medicine

Read bio

Daniel Grinberg, MD, FACS, est un oto-rhino-laryngologiste certifié par le conseil et chirurgien de la tête et du cou chez ENT and Allergy Associates à West Nyack, NY. Il a obtenu son diplôme de médecine au Columbia University College of Physicians and Surgeons, a effectué sa résidence en oto-rhino-laryngologie au New York University Medical Center, et est professeur clinique adjoint à la Mount Sinai School of Medicine. Il est membre de l'American College of Surgeons et de l'American Academy of Otolaryngology.

La perspective chirurgicale de la tête et du cou du Dr Grinberg offre aux lecteurs de PureLift LAB une vision clinique élargie — reliant la pratique EMS à domicile à l'anatomie médicale sous-jacente avec la même rigueur scientifique que celle que nous appliquons à chaque spécification d'appareil.

Prof. Dr med Ivo Buschmann

Prof. Dr med Ivo Buschmann

Président d'Angiologie, Hochschule Medizinische Brandenburg | Directeur de clinique, Clinique universitaire d'angiologie, Hôpital universitaire de Brandebourg | Ancien consultant principal, Charité Universitätsmedizin Berlin

Read bio

Le Prof. Dr. med. Ivo Buschmann est titulaire de la chaire d'angiologie à la Medizinische Hochschule Brandenburg Theodor Fontane (MHB) et directeur de la clinique universitaire d'angiologie à l'hôpital universitaire de Brandebourg. Il a effectué sa formation médicale à l'Université de Hambourg, a été boursier de la Société Max-Planck à l'Institut Max-Planck de recherche sur le cœur et les poumons, et a occupé des postes de consultant principal à la Charité Universitätsmedizin Berlin Campus Virchow avant d'être nommé titulaire de la chaire à la MHB en 2016.

Le Prof. Buschmann est l'une des principales autorités européennes en arteriogenèse — la croissance et le remodelage des vaisseaux sanguins induits par le flux — avec plus de 150 publications évaluées par des pairs et plusieurs brevets américains et européens sur des dispositifs stimulant la croissance des vaisseaux collatéraux par une thérapie contrôlée du taux de cisaillement. Ses recherches relient la stimulation mécanique et électrique à l'adaptation vasculaire, à la microcirculation et à la perfusion tissulaire.

Les contributions du Prof. Buschmann apportent aux lecteurs de PureLift LAB une perspective en biologie vasculaire qui complète notre expertise clinique, en physiothérapie et en anatomie chirurgicale — expliquant comment la stimulation EMS engage non seulement les muscles faciaux mais aussi la microcirculation qui les alimente, et pourquoi une administration intelligente est aussi importante au niveau du flux sanguin qu'à celui de la contraction musculaire.

What's This About:

This is every output figure we could find for 33 devices, with a note on whether the brand publishes it where you buy, files it with the regulator, or does not publish it at all.

This article covers what actually decides the answer, such as:

- which devices publish an output figure on their own page

- which publish one only in a regulatory filing

- which publish nothing at all

- why a figure without a stated load is not comparable

- how to use the table when you are deciding between two devices

and many more!

We will keep this page current, and we will include our own figures in it whether or not they win.

Key Points:

Of 33 devices, six publish an output figure on their own product page and two of those state the load or distance it was measured at.

A further seven publish real figures in their FDA filings and nothing on the page where the device is sold.

The remainder publish wavelengths, LED counts, programme counts and mode names, none of which tell you how hard the device works.

Current devices are listed in milliamps or microamps, light devices in mW/cm2 and J/cm2, and the two groups are not comparable with each other.

PureLift publishes 7 mA at 500 ohms for Face and Pro, 7.7 mA for Pro Edition, 9 mA for Pro Plus and GLOW, with a 4 microsecond pulse width.

How to read the table

Published on page means you can find the figure where the device is sold, without leaving the shop.

Filed only means the number exists in the manufacturer's FDA submission and nowhere on the product page.

Not published means we could not find it in either place.

Load stated matters because current through skin depends on resistance, so a milliamp figure without an ohm figure cannot be lined up against another brand's.

For light devices, the equivalent missing detail is the distance the irradiance was measured at, which no mask brand we examined states.

This comparison sits inside our full map of the category, where we set out all 33 devices we track, what each one carries and what each brand publishes: Nine Technologies on One Dial, What the Rest of the Market Actually Carries.

Current-based devices

Device Price Maximum output Load stated Where the figure lives
PureLift Face $499 7 mA Yes, 500 ohms Published on page
PureLift Pro $699 7 mA Yes, 500 ohms Published on page
PureLift Pro Edition $799 7.7 mA Yes, 500 ohms Published on page
PureLift Pro Plus $899 9 mA Yes, 500 ohms Published on page
PureLift GLOW $999 9 mA Yes, 500 ohms Published on page
Ya-Man Medi Lift PLUS JPY 33,000 3.22 mA Yes, 500 ohms Filed only
FaceGym Pro $500 1,300 to 1,700 Hz, no current figure No Partial, frequency only
FOREO BEAR 2 $339 680 microamps No Published on page
Therabody TheraFace PRO $419.99 500 microamps No Published on page
Skin Gym Microcurrent Wand $120 10 to 500 microamps No Published on page
7E MyoLift QT $229 to $329 350 microamps Yes, 500 ohms Filed only
7E MyoLift Mini $329 400 microamps No Published on page
7E MyoLift 600 Plus $1,645 600 to 650 microamps, sources disagree No Published on page
NuFACE Trinity+ $395 Not published No Not published
NuFACE MINI+ $175 to $250 335 microamps No Filed only
ZIIP Halo $399.99 309 microamps No Published on page
Solawave 4-in-1 $169 About 200 microamps Filing gives 500 ohms Both
Medicube Age-R Booster Pro X2 $249 Not published No Not published
Bio-Therapeutic bt-sculpt GEN2 About $395 Not published No Not published, filed as Statement
Droplette Device Ultra $250 No current; no velocity figure Not applicable Not published

Light-based devices

Device Price Irradiance Delivered dose Where the figure lives
PureLift GLOW light layer $999 0.113 mW/cm2 0.068 J/cm2 Published on page
Shark CryoGlow $349.99 128 mW/cm2 Up to 431 J/cm2 Filed only
HigherDOSE Red Light Mask $349 50 mW/cm2 30 J/cm2 Irradiance on page, dose filed
Omnilux Contour Face $395 About 30 mW/cm2 Not published Irradiance on page
Silk'n LED Face Mask 100 $299 About 28.5 mW/cm2 Not published Published on page
CurrentBody Series 2 $569.99 Not published 18 J/cm2 Filed only
CurrentBody Series 3 $569.99 13 to 26 mW/cm2 by wavelength Not published Filed only
Qure Q-Rejuvalight Pro $399 15 to 70 mW/cm2 by mode Not published Filed only
Solawave 4-in-1 $169 55 mW/cm2 9.9 J/cm2 per area Published on page
Dr Dennis Gross FaceWare Pro $455 Not published Not published Not published
FOREO FAQ 202 $799 Not published Not published Not published
Therabody TheraFace Mask $649.99 Not published Not published Not published
FaceGym LIGHTWEAR $545 Not published Not published Not published

Laser and radiofrequency devices

Device Price Published output Where the figure lives
LYMA Laser GBP 1,999 808 nm and 620 nm, about 62.5 mW/cm2 over 8 cm2 Published on page
NIRA Precision $449 1450 nm, power not published Partial
NEWA Skin Therapy System From $339 1 MHz, up to 10 W, 42 C cutoff Filed only, De Novo
TriPollar STOP Vx About $699 Not published for the home device Not published
Silk'n Titan MultiPlatform $549 43 C cap only Not published

What the table shows

Six devices out of 33 publish an output figure where the device is sold, and two of those state the conditions it was measured under.

Seven more publish genuine engineering to the FDA and nothing to the buyer, which is the single clearest pattern in this category.

The devices that publish nothing at all are spread across every price point, including the most expensive mask in the set.

Nothing in this table proves any device works, and it does show you which brands are willing to be held to a number.

Figures verified on 21 September 2026 against each brand's own published material and the FDA 510(k) database.

Retour au blog